Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Open Forum Infect Dis ; 9(9): ofac431, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-2037499

ABSTRACT

The presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on surfaces at public locations has been minimally described. By swab testing, we investigated the presence of SARS-CoV-2 on surfaces in public locations during the pandemic in February 2022. The viability of SARS-CoV-2 was not tested. Almost 25% of surfaces were positive for SARS-CoV-2; this was most pronounced in supermarkets.

2.
Open forum infectious diseases ; 2022.
Article in English | EuropePMC | ID: covidwho-2012150

ABSTRACT

The presence of SARS-CoV-2 on surfaces at public locations is minimally described. By swab-testing, we investigated the presence of SARS-CoV-2 on surfaces in public locations during the pandemic in February 2022. The viability of SARS-CoV-2 was not tested. Almost 25% of surfaces were positive for SARS-CoV-2;most pronounced in supermarkets.

4.
J Clin Microbiol ; 59(5)2021 04 20.
Article in English | MEDLINE | ID: covidwho-1195815

ABSTRACT

Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to support clinical diagnosis and epidemiological investigations. Recently, assays for large-scale detection of total antibodies (Ab), immunoglobulin G (IgG), and IgM against SARS-CoV-2 antigens have been developed, but there are limited data on the diagnostic accuracy of these assays. This study was a Danish national collaboration and evaluated 15 commercial and one in-house anti-SARS-CoV-2 assays in 16 laboratories. Sensitivity was evaluated using 150 samples from individuals with asymptomatic, mild, or moderate COVID-19, nonhospitalized or hospitalized, confirmed by nucleic acid amplification tests (NAAT); samples were collected 13 to 73 days either from symptom onset or from positive NAAT (patients without symptoms). Specificity and cross-reactivity were evaluated in samples collected prior to the SARS-CoV-2 epidemic from >586 blood donors and patients with autoimmune diseases, cytomegalovirus or Epstein-Barr virus infections, and acute viral infections. A specificity of ≥99% was achieved by all total-Ab and IgG assays except one, DiaSorin Liaison XL IgG (97.2%). Sensitivities in descending order were Wantai ELISA total Ab (96.7%), CUH-NOVO in-house ELISA total Ab (96.0%), Ortho Vitros total Ab (95.3%), YHLO iFlash IgG (94.0%), Ortho Vitros IgG (93.3%), Siemens Atellica total Ab (93.2%), Roche Elecsys total Ab (92.7%), Abbott Architect IgG (90.0%), Abbott Alinity IgG (median 88.0%), DiaSorin Liaison XL IgG (median 84.6%), Siemens Vista total Ab (81.0%), Euroimmun/ELISA IgG (78.0%), and Snibe Maglumi IgG (median 78.0%). However, confidence intervals overlapped for several assays. The IgM results were variable, with the Wantai IgM ELISA showing the highest sensitivity (82.7%) and specificity (99%). The rate of seropositivity increased with time from symptom onset and symptom severity.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay , Cytomegalovirus Infections , Enzyme-Linked Immunosorbent Assay , Epstein-Barr Virus Infections , Herpesvirus 4, Human , Humans , Immunoglobulin G/isolation & purification , Immunoglobulin M/isolation & purification , Laboratories , SARS-CoV-2 , Sensitivity and Specificity
5.
Diagnostics (Basel) ; 10(9)2020 Sep 09.
Article in English | MEDLINE | ID: covidwho-760895

ABSTRACT

The aim of this study was to compare the sensitivity of self-collected versus healthcare worker (HCW)-collected swabs for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) testing. Symptomatic individuals referred for SARS-CoV-2 testing were invited to provide mobile-phone video-instructed self-collected oropharyngeal and nasal samples followed by a HCW-collected oropharyngeal sample. All samples were sent for analysis to the same microbiology laboratory, and the number of SARS-CoV-2-positive participants in the two tests was compared. A total of 109 participants were included, and 19 participants had SARS-CoV-2-positive results. The diagnostic sensitivity of the self-collected and HCW-collected swabs was 84.2% and 89.5%, respectively, with an acceptable agreement, Cohens kappa 0.82, p < 0.001. Further, results from a questionnaire answered by the participants found that loss of smell as a self-reported symptom was a strong predictor for a SARS-CoV-2-positive test. In conclusion, we found that self-collected oropharyngeal and nasal swabs for SARS-CoV-2 testing can be reliable compared to HCW-collected oropharyngeal samples.